30 Days Return Policy. Learn more

Click here to contact us.

SpareCrux

SPARECRUX is NOT an authorized distributor for ALLEN BRADLEY

100S-E38EJ31C | ALLEN BRADLEY | Safety Contactor,IEC,38A,24 60V 50 60 Hz/20 60V DC Low Consumption,3 NO Poles,0 NO 0 NC Auxiliary Contacts,3 NO 1 NC

₹ 12,891.22

₹ 10,924.76 (Excl. Tax)


Warranty

We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.

Delivery and Shipping

We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.

Manufacturer Part Number (MPN)

100S-E38EJ31C

Original Equipment Manufacturer

ALLEN BRADLEY

Description

Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 24 V
Rated control supply voltage at AC 60 Hz 24 V
Rated control supply voltage at DC 20 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Operating time, opening delay 11 ms
Optional overload relays Electronic
Main current circuit resistance 0.21 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing safety contactor
Energy-efficient coil, hold-in 1.7VA/1.7 W @ 24-60V AC, 20-60V DC
Energy-efficient coil, pick-up 16VA/12...16 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed) 24A @ 600V per UL/CSA
Power dissipation 3 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 600A @ 10s (40 °C)
ALLEN BRADLEY

100S-E38EJ31C | ALLEN BRADLEY | Safety Contactor,IEC,38A,24 60V 50 60 Hz/20 60V DC Low Consumption,3 NO Poles,0 NO 0 NC Auxiliary Contacts,3 NO 1 NC

₹ 10,924.76
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 24 V
Rated control supply voltage at AC 60 Hz 24 V
Rated control supply voltage at DC 20 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Operating time, opening delay 11 ms
Optional overload relays Electronic
Main current circuit resistance 0.21 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing safety contactor
Energy-efficient coil, hold-in 1.7VA/1.7 W @ 24-60V AC, 20-60V DC
Energy-efficient coil, pick-up 16VA/12...16 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed) 24A @ 600V per UL/CSA
Power dissipation 3 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 600A @ 10s (40 °C)
View product
Powered by Omni Themes